Control · the processor.

We write the control strategy, specify the building management system, and make BACnet, KNX and Modbus devices behave as one system rather than three that happen to share a building.

A building management system is usually procured as a product and delivered as a wiring exercise. The part that determines whether the building is efficient — the sequence of operation — is often left to whoever commissions the panel, and is rarely written down in a form anyone can audit.

We treat the control strategy as a design deliverable in its own right: written before tender, specified in vendor-neutral terms, and testable at handover. That is what makes a BMS an asset instead of an ongoing complaint.

What we do

What we do

BMS strategy and architecture

What is controlled where, which layer owns which decision, and how the system degrades when part of it fails.

Sequences of operation

Written, reviewable control sequences — setpoints, resets, interlocks, staging and mode changes — specified so they survive handover.

BACnet, KNX and Modbus integration

Protocol selection and gateway design, so room-level and plant-level systems exchange the right data instead of the data that happened to be available.

HVAC, lighting and shading control

Coordinated control across domains, including daylight, glare and solar gain, rather than four subsystems fighting one another.

Vendor-neutral tender specification

Points lists, integration requirements and acceptance criteria written so more than one integrator can bid — and so you can change integrator later.

Commissioning support

Witnessing that the sequences actually do what the specification says, function by function.

How we work

How we work

  1. 01

    Control philosophy

    What the building should do, in plain language, before any product is named.

  2. 02

    Points and architecture

    Points list, network topology, protocol boundaries and the gateway strategy between them.

  3. 03

    Sequences of operation

    Function-by-function sequences with setpoints, resets and interlocks written out in full.

  4. 04

    Tender and award

    Vendor-neutral specification, tender review, and technical comparison of integrator proposals.

  5. 05

    Witness and accept

    Functional testing against the written sequences, with a defect list that closes.

What you get
  • Control philosophy document
  • Points list and network architecture
  • Written sequences of operation
  • Protocol and gateway specification
  • Vendor-neutral BMS tender specification
  • Functional test scripts and witness records
Common questions
Should we use BACnet, KNX or Modbus?

Usually more than one. KNX suits room-level lighting, shading and terminal control; BACnet suits plant and supervisory levels; Modbus is how most meters, drives and chillers will talk to you regardless. The design decision is where the boundaries sit and who owns the gateway — not picking a single winner.

We already have a BMS that underperforms. Can that be fixed without replacing it?

Very often, yes. In our experience most underperformance is in the sequences and setpoints rather than the hardware. A controls audit against a written specification usually finds a substantial share of the gap before any capital spend.

Do you work with a particular BMS manufacturer?

No. We specify in open, vendor-neutral terms so the tender stays competitive and you are not locked into one integrator for the life of the building.